you are here : Home » Shop » Emergency Resuscitation Equipment » SUREVENT 2 EMERGENCY VENTILATOR RESUSCITATOR


SUREVENT 2 EMERGENCY VENTILATOR RESUSCITATOR
SMVTR001

- SureVent 2 (SV2) constant flow, pressure cycled providing desired airway pressure and i:e ratio
- Gas powered, attaches to oxygen flow meter and utilises minimum 8 l/min or 15 l/min with new entrainment valve
- Readily usable, uncomplicated, simple activation and security locked pre settings for use
- Ventilates children to a weight 8Kg < & adults
- Utilised in resuscitation to ventilate via ETT or Laryngeal mask freeing up a rescuer or single operator
- Automatically adjusts for lung compliance, key in ARDS and prevention of barotrauma
- Pressure cycled on inhalation and exhalation minimizing the possibility of gas trapping
- Disposable, single use, no cleaning or sterilisation, reduced cost of consumables, hardware, servicing and education
- Intrinsic PEEP of 25% of PIP, no PEEP valve required
- 5 year shelf life
- Removing the electronic manometer, makes SureVent 2 (SV2) MRI compatible
- Electronic Digital Manometer with visual and audible alarms for occlusion, disconnection, low battery and manometer failure
- Electronic Manometer, illuminated LCD screen will display the pressure with each breath and the BPM
 
Key clinical advantages of SUREVENT 2 (SV2) pressure controlled ventilation
1) Control of delivered pressure and breath rate
2) Reduces the risk of hyperinflation, barotrauma from resuscitation bagging
3) Minimalises the risk of aerophagia and aspiration
4) Control over oxygen and carbon dioxide levels
5) Lung auscultation can be performed for air entry for ETT position or assessment
 
Key field / operational advantages of SUREVENT 2 (SV2)
1) Reduces personnel, with safer patient transportation as no one needs to bag ventilate the patient
2) Improves quality of care and reduces risk to patient
a. Reduced chance of extubation
b. Uninterrupted ventilations during movement
c. Safer ventilation
d. Lessen risk of vomiting and aspiration
3) Minimal training and expertise to ventilate patients
4) Can be used for ETT and Face Mask ventilation
 
Operational Specifications SUREVENT 2 (SV2)
- Recommended for body weights of 8 kg and higher
- Ventilation frequency: Manual/Auto-adjusting to lung capacity 8 to 30+ BPM
- Adjustable PIP: 10 to 40+ cm H2O
- PEEP: equal to 25% or 1/4 of PIP (2 to <12+ cm-H2O)
- POP off safety valve 55cm H20
- Inspiratory resistance: 3 ± 1 cm-H2O/L/sec
- Expiratory resistance: 3 ± 1 cm-H2O/L/sec
- Dead space: 4 ± 3 ml
- Pressure Alarm: ³ 2 cmH20 or £ 60cm H20 . Non cycle alarm < 8 BPM
- Electronic manometer: self testing, failure/ low battery alarm and four hour battery life
- Environmental: Operating limits -10 to +45°C / Storage limits -20 to 75°C
- Patient connection: 15 mm / 22 mm, Gas inlet: DISS or Flowmeter Nipple connection
- Oxygen concentration: 100% FiO2 at 15l/min or 65% with ambient entrainment port open at 8 l/min
- All quantified specifications are ± 10%
 

AUD$245.00

 